ISP/ISPT 474 – Picotherm

Features

  • Compact design
  • Rugged housing
  • High repeatability
  • Protection IP65
  • Any mounting position possible
Product request

Downloads

Approvals

×
This is a mandatory field
Please enter your email address!
CAPTCHA image for SPAM prevention If you can't read the word, click here.

Technical Data

Applications

Shipbuilding, Engine manufacturing, Railways, Hydraulics, HVAC

Category

Hydraulic

Accuracy @ 25°C typ.

± 0.5 % FS typ.

Dielectric strength

2 kV terminal ground

Measuring principle

Thick-film-on-ceramic

Vibration

5...25 Hz: ±1.6 mm
25...100 Hz: 4g

NLH @ 25°C (BSL) typ.

± 0.2 % FS typ.

Pressure connections

G1/4" f, G1/4" m, G1/2" m DIN3852-A, G1/2" m DIN3852-E, 1/4"NPT m ANSI B1.20.1, 1/8"NPT m ANSI B1.20.1, 7/16"-20UNF m SAE4, 7/16”-20UNF m, DIN3866, 7/16”-20UNF f SAE J512 with valve opener, R1/4" m DIN3858, G3/4" frontal membrane

Media temperature

+5°C ... +150°C

Shock

50 g / 11 ms

Electrical connections

EN175301-803-A (DIN43650-A); M12x1; Industrial standard, contact distance 9.4 mm; Packard Metri Pack; Cable

Long term stability 1 year typ.

± 0.3 % FS typ.

Ambient temperature

-30°C ... +70°C

Protection

IP65

Output signal

Floating change-over contact

Approval / conformity

ABS, BV, CCS, DNV, GL, KRS, LRS, NKK, RINA, RMRS
EN60730-1/ EN60730-2-9: Typ 2.B.H

TEB typ. @ -25 ... +85°C

± 3.0 % FS typ.

Measuring range

+5°C ... +95°C to +20°C ... +150°C